جی ام اینترنشنال ایتالیا GMI

بریر, ایزولاتور, رله SIL 3

vip
vip

رله ایمنی Safety Relay D1092D , D1093S , D5098

رله ایمنی SIL3 تک کاناله SIL 3 Certified Safety Relay for Hazardous Area D5000, D1000, D1092, D1093, D5090, D5091, D5094, D5095, D5096, D5097, D5098, D5290, D5291, D5292, D5293, D5294, D5295, قابلیت Line Monitoring D1092S, D1092D, D1093S, D5091S, D5096S, D5294S,

مشخصات

شرکت سازنده :
GMI - GM INTERNATIONAL
مدل :
سری D1000 و سری D5000
کشور سازنده :
ایتالیا
D1092D :
SIL3 Relay D1000 2 Ch, 4SPST, 3A
D5095S :
SIL3 Relay D5000 1 Ch, NE/ND 2 SPST, 5A
D5094S :
SIL3 Relay D5000 1 Ch, NE/ND 2 SPST, 5A
D1092S :
SIL3 Relay D1000 1 Ch, 2SPST, 3A
D5091S :
SIL3 Relay D5000 1 Ch, ND SPST, 5A
D5090S :
SIL3 Relay D5000 1 Ch, NE SPST, 5A
D5294S :
SIL3 Relay D5000 1 Ch, ND 1+1SPST, 5A
D1093S :
SIL3 Relay D1000 1 Ch, 2SPST, 3A Line de
قیمت محصول
حداقل مقدار سفارش :
1 عدد

توضیحات محصول

 رله ایمنی مدل D1092D  و D1093S

Safety Relay 

SIL Certified Relays are used for critical loops where careful consideration should be
given to Line and Load Monitoring. In a De-energize to Safety application a wire/coil
failure leads to a safety status. In an Energize to Safety application line failures leads to a
dangerous status. In both cases failure detection is important, if not essential.
Other diagnostics applications are monitoring the Load status to prevent spurious trips or
to verify the condition of the individual coil in a redundant coil SOV. In F&G system line
diagnostics is a must and regulated by NFPA 72 code.
Control system diagnostic capabilities are designed to work when no device is interposed
between the control system and the load. If a relay is placed in the loop, the diagnostic
function stops at the relay input circuit (coil). To perform line monitoring from field device
to controller, a SIL relay with built-in diagnostic circuit is required. GM International relays
will perform diagnostics of the load, wire, power supply and internal coils in all operating
conditions; providing an independent alarm contact as well as transparently transferring
.

• Reduced Foot Print: High Density: 12,5/22,5 mm per Ch.
• Full 3rd Party Certification: Coil-to-Contact SIL2/3 TÜV
certified
• True Reliability: Compatible to DO Card LM Pulses
• Reduced Space/Eng. Costs: Smart Line/Load Monitoring
with transparent Fault Indication (no additional contacts)
• Lower Ownership/Maintenance Cost: T-proof Times: 10/20
years
• Reduced Spare Inventory: Universal Mounting: DIN-Rail
and Termination Boards
• Higher Reliability In & Outdoor: Certified -40° to + 70° C
• Totally independent Dual Ch.: Dual circuits
• Full Application Coverage: Modules available with 5 & 10
Amps Contact, NE/ND application
• Harsh environment resistance: G3 conformal coating
• Reliable switching operations: gold-plated relay contactsthe fault indication to compatible DO cards.

در صورت نیاز به اطلاعات بیشتر با نمایندگی جی ام آی تماس بگیرید. 